Rockwell Automation 1440-VSE02-01RA XM-122 gSE Vibration Module User Manual

Page 141

Advertising
background image

Publication GMSI10-UM013D-EN-P - May 2010

DeviceNet Objects 131

Instance 199 - Dynamic Assembly

This Assembly instance can be created and configured with the XM Serial
Configuration Utility or RSMACC Enterprise Online Configuration Utility.
Using the configuration software, you determine the format of the data. This
assembly instance can be selected to be sent in response to an I/O Poll request
from a Master.

The dynamic Assembly can include all of the measurement values included in
Assembly instance 101. In addition, the dynamic Assembly can include the
following configuration parameters.

28 - 31

Channel 1 Band 1 value

32 - 35

Channel 2 Band 1 value

36 - 39

Channel 1 Band 2 value

40 - 43

Channel 2 Band 2 value

44 - 47

Channel 1 Band 3 value

48 - 51

Channel 2 Band 3 value

52 - 55

Channel 1 Band 4 value

56 - 59

Channel 2 Band 4 value

60 - 63

Channel 1 Sum Harmonics value (AIP Object Instance #7)

64 - 67

Channel 2 Sum Harmonics value (AIP Object Instance #8)

68 - 71

Channel 1 Not 1X value (AIP Object Instance #3)

72 - 75

Channel 2 Not 1X value (AIP Object Instance #4)

76 - 79

Channel 1 Vector 1 Phase value

80 - 83

Channel 2 Vector 1 Phase value

84 - 87

Channel 1 Vector 2 Phase value

88 - 91

Channel 2 Vector 2 Phase value

92 - 95

Channel 1 Vector 3 Magnitude value

96 - 99

Channel 2 Vector 3 Magnitude value

100 - 103

Channel 1 Gap value (AIP Object Instance #1)

104 - 107

Channel 2 Gap value (AIP Object Instance #2)

108 - 111

Maximum Speed value

112 - 115

Channel 1 gSE Overall value (AIP Object Instance #5)

116 - 119

Channel 2 gSE Overall value (AIP Object Instance #6)

120 - 123

Acceleration value

Table C.16 Instance 103 Data Format (Measurement Values Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0