Rockwell Automation 1440-VSE02-01RA XM-122 gSE Vibration Module User Manual

Page 136

Advertising
background image

Publication GMSI10-UM013D-EN-P - May 2010

126 DeviceNet Objects

Instance 102 - Measurement Values

This assembly instance can be selected to be sent in response to an I/O Poll
request from a Master. This instance includes all of the channel 1 parameters
first.

84 - 87

Channel 2 Vector 2 Phase value

88 - 91

Channel 1 Vector 3 Magnitude value

92 - 95

Channel 2 Vector 3 Magnitude value

96 - 99

Channel 1 Not 1X value (AIP Object Instance #3)

100 - 103

Channel 2 Not 1X value (AIP Object Instance #4)

104 - 107

Channel 1 gSE Overall value (AIP Object Instance #5)

108 - 111

Channel 2 gSE Overall value (AIP Object Instance #6)

112 - 115

Channel 1 Sum Harmonics value (AIP Object Instance #7)

116 - 119

Channel 2 Sum Harmonics (AIP Object Instance #8)

120 - 123

Acceleration value

Table C.11 Instance 101 Data Format (Measurement Values Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Table C.12 Instance 102 Data Format (Measurement Values Assembly)

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0 - 3

Speed value

4 - 7

Channel 1 Overall value

8 - 11

Channel 1 gSE Overall value (AIP Object Instance #5)

12 - 15

Channel 1 Band 1 value

16 - 19

Channel 1 Band 2 value

20 - 23

Channel 1 Vector 1 Magnitude value

24 - 27

Channel 1 Vector 2 Magnitude value

28 - 31

Channel 1 Vector 3 Magnitude value

32 - 35

Channel 1 Band 3 value

36 - 39

Channel 1 Band 4 value

40 - 43

Channel 1 Vector 1 Phase value

44 - 47

Channel 1 Vector 2 Phase value

48 - 51

Channel 1 Gap value (AIP Object Instance #1)

52 - 55

Channel 1 Not 1X value (AIP Object Instance #3)

56 - 59

Channel 1 Sum Harmonics value (AIP Object Instance #7)

60 - 63

Acceleration value

64 - 67

Channel 2 Overall value

68 - 71

Channel 2 gSE Overall value (AIP Object Instance #6)

Advertising