Cos message format – Rockwell Automation 1440-VSE02-01RA XM-122 gSE Vibration Module User Manual

Page 124

Advertising
background image

Publication GMSI10-UM013D-EN-P - May 2010

114 DeviceNet Information

COS Message Format

The XM-122 COS message contains eight bytes of data as defined in the table
below. The COS data can also be requested explicitly through Assembly
Object (Class ID 0x4), Instance 100 (0x64), Data Attribute (3).

XM Status Values

The following tables describe the XM Status values that are included in the
COS messages.

XM-122 COS Message Format

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Relay 1
Status

Setpoint
Multiplier
Status

Alarm 2 Status

Alarm 1 Status

1

Relay 2
Status

Reserved

Alarm 4 Status

Alarm 3 Status

2

Relay 3
Status

Reserved

Alarm 6 Status

Alarm 5 Status

3

Relay 4
Status

Reserved

Alarm 8 Status

Alarm 7 Status

4

Relay 5
Status

Reserved

Alarm 10 Status

Alarm 9 Status

5

Reserved

Reserved

Alarm 12 Status

Alarm 11 Status

6

Reserved

Reserved

Alarm 14 Status

Alarm 13 Status

7

Reserved

Reserved

Alarm 16 Status

Alarm 15 Status

Alarm Status Descriptions

Alarm Status Value

Description

0

Normal

1

Alert

2

Danger

3

Disarm

4

Transducer Fault (Sensor OOR)

5

Module Fault

6

Tachometer Fault

7

Reserved

Advertising