Publication GMSI10-UM013D-EN-P - May 2010

Installing the XM-122 gSE Vibration Module 35

Figure 2.23 Powered Sensor to Channel 1 Wiring

Figure 2.24 Powered Sensor to Channel 2 Wiring

0

16

37

+24V DC

Common

Signal

5

6

Channel 1 Input Signal

Signal Common

Shield

+24V DC

TYPICAL WIRING FOR MODEL 580 VIBRATION PICKUP

TO XM-122 VIBRATION MODULE CHANNEL 1

Cable shield not
connected at this end

25

Jumpering terminal 5
to terminal 6 configures
CH 1 buffer for -5V to +24V

1

17

38

+24V DC

Common

Signal

6

22

Channel 2 Input Signal

Signal Common

Shield

+24V DC

TYPICAL WIRING FOR MODEL 580 VIBRATION PICKUP

TO XM-122 VIBRATION MODULE CHANNEL 2

Cable shield not
connected at this end

Jumpering terminal 6
to terminal 22 configures
CH 2 buffer for -5V to +24V

25