3. Remove the PCI fan assembly, including the flex cable that covers it. For

instructions, see

Section 5.2.4, “Replacing the PCI Fans in the Fan Shroud” on

page 105

.

4. Remove the CPU fan assembly. For instructions, see

Section 5.2.1, “Removing the

CPU Fans” on page 100

.

5. Disconnect all of the cables connected to the SFP board:

— SAS backplane power cable
— All four fan power cables
— Two power input cables from the power distribution board
— Flex cable
— RAID IBBU cable, if installed
— Front serial port cable

Use

Section 33, “NSC2U Server System Cable Routing” on page 51

as a reference

for all of the connectors.

6. Remove the bridge board by opening the connector latch (

Figure 94

, “A”) and lifting

the board up from both ends. (“B”)

Figure 94.

Removing the Bridge Board

TS000565