NSC2U Server—Server Component Installations and Upgrades

Kontron IP Network Server NSC2U

Product Guide, rev. 1.4

December 2009

34

Table 6

gives the possible configuration options. This jumper should only be moved if

you wish to force the BIOS to boot to the secondary bank, which may hold a different

version of BIOS.

The rolling BIOS feature of the baseboard automatically alternates the Boot BIOS to

the secondary bank in the event that the BIOS image in the primary bank is corrupted

and cannot boot for some reason.

Note:

When performing a BIOS update procedure, the BIOS select jumper must be set to its

default position (pins 2-3).

3.4.1.3

DCD/DSR Signal Select Jumper

Note:

This jumper affects the rear panel serial port only.

Various serial port concentrators may require either the DCD (Data Carrier Detect) or

DSR (Data Signal Ready) signal on Pin 7 of the RJ45 connector. To allow support for

either of these two serial port configuration standards, a jumper block (J8A3) located

directly behind the rear RJ45 serial port (see

Figure 19

) must be configured

appropriately according to the desired standard:

• For configurations that are compatible with Cisco serial concentrators and require a

DSR signal, the jumper block must be configured with the serial port jumper over

pins 3 and 4. This is the factory-installed default setting for this jumper.

Figure 18.

BIOS Select Jumper (J3H1)

Table 6.

BIOS Select Jumper

Pins

What happens at system reset…

1-2

Force BIOS to bank 0

2-3

System is configured for normal operation (Default)