13 hard drive(s) are not recognized, 5 led information, Led information – Kontron NSC2U IP Network Server User Manual

Page 131: If system leds are illuminated, see, Section 7.5

Advertising
background image

Kontron IP Network Server NSC2U

December 2009

Product Guide, rev. 1.4

131

 If you suspect that a transient voltage spike, power outage, or brownout might

have occurred, reload the software and try running it again. Symptoms of voltage

spikes include a flickering video display, unexpected system reboots, and the

system not responding to user commands.

Note:

For AC power, if you are getting random errors in your data files, they may be getting

corrupted by voltage spikes on your power line. If you are experiencing any of the

above symptoms that might indicate voltage spikes on the power line, you may want to

install a surge suppressor between the power outlet and the system power cord.

7.4.12

Devices are not Recognized under Device Manager (Windows*

OS)

The Windows* operating systems do not include all of the drivers for the Intel

®

chipsets, onboard NICs, and other components. See

http://us.kontron.com/support/

for a link to the current drivers and chipset files.

7.4.13

Hard Drive(s) are not Recognized

Check the following:

 Make sure the drive is not disabled in BIOS Setup.

 Make sure the drive is compatible. Go to

http://us.kontron.com/support/

for a link to the list tested drives.

 Make sure you have not exceeded the power budget for the server. Go to

http://us.kontron.com/

support/ for a link to software to check your power budget.

7.5

LED Information

The Intel® Server Board T5000PAL includes LEDs that can aid in troubleshooting your

system.

Table 14

defines these LEDs with a description of their use.

Table 14.

LED Definitions (Sheet 1 of 2)

LED Name

Function

Location

Color

Notes

ID

Aid in server

identification from

the back panel

Control panel and

rear left corner of

server board

Blue

Press ID LED button or user

Server Management

software to turn on the LED.

System fault

Visible fault warning

Control panel and

rear left corner of

server board

Green or

Amber

Green = No Fault
Green blinking = degraded
Amber = critical error or

non-recoverable
Amber blinking = non-

critical error

ATA drive activity

Control panel

Control panel

Green

Blinking = Activity. No action

required.

Memory fault 1–6

Identify failing

memory module

DIMM end rear of

server board

Amber

On = Fault

Diagnostic LEDs.

1–4 (LSB, bit1,

bit2, MSB)

Displays port 80

POST codes

Center back edge

of server board

Each LED can

be Off, Green,

Amber, Red

See the POST code table

CPU 1 & 2

Fan Fault

Identify fan failure

Front center of

server board

Amber

On = Fault

Advertising