4 hard disk drive and power supply cooling, 5 fan speed control, 6 cooling summary – Kontron NSC2U IP Network Server User Manual

Page 23

Advertising
background image

Kontron IP Network Server NSC2U

December 2009

Product Guide, rev. 1.423

Features—NSC2U Server

2.10.4

Hard Disk Drive and Power Supply Cooling

Airflow to cool the hard disk drives is provided by the fans that are integrated into the

PSUs. The airflow is adequate even with a single PSU installed as long as a filler panel is

installed in the other PSU slot.

2.10.5

Fan Speed Control

The server board contains Pulse Width Modulation (PWM) circuits, which control the

12 Vdc fan voltage to provide quiet operation when system ambient temperature is low

and there are no fan failures. There is one PWM circuit for each cooling domain,

resulting in one PWM being connected to each of the two 80×38 mm fans and the other

PWM connected to the two dual-rotor 56×40 mm fans. Based on the ambient

temperature, monitored by the front panel sensor, the fan speeds (PWM duty cycle) are

set per

Table 4

.

2.10.6

Cooling Summary

The four-fan cooling subsystem of the NSC2U Server is sized to provide cooling for:

• up to two server board processors
• up to 32 Gbytes of FB DIMM memory
• up to six SAS hard drives
• up to five PCI add-in cards consuming a maximum of 25W for each full-height

PCI-X/PCIe add-in cards and 10W for each low-profile PCIe add-in card

The cooling subsystem is designed to meet acoustic and thermal requirements at the

lower fan speed settings. At the higher fan speed settings, thermal requirements are

met for the maximum ambient temperatures, but acoustic requirements are not met.

Table 4.

Fan Speed Settings

Temperature (°C)

CPU1 Fan

PWM DC (%)

CPU2 Fan

PWM DC (%)

PCI Fans

PWM DC (%)

0 - 28

46

46

46

29

47

47

47

30

48

48

48

31

53

53

53

32

58

58

58

33

63

63

63

34

68

68

68

35

73

73

73

36

78

78

78

37

84

84

84

38

89

89

89

39

95

95

95

40

100

100

100