4 removing memory dimms, Removing memory dimms, Figure 24 – Kontron NSC2U IP Network Server User Manual

Page 42

Advertising
background image

NSC2U Server—Server Component Installations and Upgrades

Kontron IP Network Server NSC2U

Product Guide, rev. 1.4

December 2009

42

3. Open both DIMM socket levers. (“A”)
4. Note the location of the alignment notch. (“B”)
5. Insert the DIMM making sure the connector edge of the DIMM aligns correctly with

the slot. (“E”)

6. Using both hands, push down firmly and evenly on both sides of the DIMM until it

snaps into place and the levers close. (“C” and “D”)
IMPORTANT: Visually check that each latch is fully closed and correctly engaged

with notch on the DIMM edge. (“E”)

7. Replace the air duct and chassis cover if you have completed all work inside of the

server.

3.4.4

Removing Memory DIMMs

Reduce the risk of electrostatic discharge (ESD) damage to the DIMMs and server

board by doing the following:

• Touch the metal chassis before touching the DIMM or server board.

Figure 24.

Installing Memory DIMMs

TS000278

E

A

C

D

B

DIMM A1

DIMM A2

DIMM B1

DIMM B2

DIMM D2

DIMM D1

DIMM C2

DIMM C1

Branch 0
Branch 1