4 clearing the password, 5 bmc force update procedure, Clearing the password – Kontron NSC2U IP Network Server User Manual

Page 125: Bmc force update procedure

Advertising
background image

Kontron IP Network Server NSC2U

December 2009

Product Guide, rev. 1.4

125

6.4

Clearing the Password

If the user or administrator password(s) is lost or forgotten, moving the password clear

jumper into the “clear” position clears both passwords. The password clear jumper

must be restored to its original position before a new password(s) can be set. The

password clear jumper (J1D2) is shown in

Figure 17, “Recovery Jumper Blocks (J1D1,

J1D2, J1D3)” on page 33

.

1. Power down the system and disconnect the power.
2. Open the server chassis. See

Section 3.2.1

,

“Removing the Chassis Cover”

for

instructions.

3. Move the jumper (J1D2) from the normal operation position, Password Clear

Protect, at pins 1 and 2 to the Password Clear Erase position, covering pins 2 and 3.

4. Reconnect the power, power up the system.
5. Power down the system and disconnect the power cord.
6. Return the Password Clear jumper (J1D2) to the Password Clear Protect position,

covering pins 1 and 2.

7. Close the server chassis. See

Section 3.2.2

,

“Installing the Chassis Cover”

for

instructions.

8. Reconnect the power and power up the server.

6.5

BMC Force Update Procedure

When performing a standard BMC firmware update procedure, the update utility places

the BMC into an update mode to allow the firmware to load safely onto the flash device.

In the unlikely event that the BMC firmware update process fails because the BMC is

not in the proper update state, the server board provides a BMC Force Update jumper

that can force the BMC into the proper update state. Use the following procedure if the

standard BMC firmware update process fails.

Once the firmware update process completes successfully, the firmware update utility

may generate an error stating that the BMC is still in update mode. Use the following

procedure to get out of Update mode:

1. Power down and remove the power cord.
2. Open the server chassis (remove the top cover).
3. Locate jumper block J1D1 and move the jumper to the Enable position (pins 2-3).
4. Close the server chassis.
5. Reconnect the power and restart the system.

Now perform the standard BMC firmware update procedure as documented in the

README.TXT file included in the BMC Firmware Update package.

Note:

Normal BMC functionality is disabled when the Force BMC Update jumper is populated.

The server should never be run with the BMC Force Update jumper populated and this

header should only be used when the standard firmware update process fails. This

header should remain unpopulated by default when the server is running normally.

6. When the update has finished, power down the system and remove the power cord.
7. Open the server chassis (remove the top cover).
8. Close the server chassis.
9. Reconnect the power and restart the system.

10. Locate jumper block J1D1 and move the jumper to the Disable position (pins 1-2).

Advertising