background image

Kontron IP Network Server NSC2U

December 2009

Product Guide, rev. 1.4

57

Optional Component Installations—NSC2U Server

4.4

Installing Intel

®

Remote Management Modules

To install the GCM module and Remote Management Module (RMM), you must first

remove the chassis top cover, the processor air duct, and PCI riser card assembly.

4.4.1

Installing the GCM Module

1. Remove the filler panel from the rear panel of the chassis by squeezing the side

edges and pulling it out. (

Figure 39

)

2. Snap the two standoffs into the server board. (

Figure 40

, “C”)

3. Attach the module to the server board using the connector. (“D”)
4. If this is the last task you are performing, replace the riser card assembly, the

processor air duct, and the top cover of the chassis. Reconnect all the external

devices and plug in the power cord(s).

For information about mounting the server in a rack, see

Section 3.5, “Installing

the Server into a Rack” on page 48

.

4.4.2

Installing the RMM Module

1. Remove the PCI riser card assembly to access the RMM site on the T5000PAL

server board. (For instructions, see

Section 4.2.2

,

“Removing the PCI Riser Card

Assembly”

.)

2. Snap the standoff into the T5000PAL server board. (

Figure 40

, “A”)

3. Fasten the RMM module to the server board site using the connector (“B”) and the

standoff hole.

Figure 39.

Removing the GCM Port Filler Panel

TS000548