Kontron NSC2U IP Network Server User Manual

Page 64

Advertising
background image

NSC2U Server—Optional Component Installations

Kontron IP Network Server NSC2U

Product Guide, rev. 1.4

December 2009

64

1. Remove the filler panel from one of the front panel 4xGbE port slots by loosening

the two screws and pulling the filler panel down from the top edge and out.

(

Figure 47

, “A” and “B”)

2. Insert the 4xGbe port escutcheon by first fitting the two tabs on the top into the

front panel opening and then fastening the escutcheon with the two screws

removed from the filler panel with a Phillips screwdriver. (

Figure 48

, “A” and “B”)

3. Insert the 4xGbE connector assembly in the escutcheon with the four ports (A

through D) in the order illustrated in

Figure 49

. (“A”)

4. Fasten the 4xGbE connector assembly to the escutcheon with the two screws, using

a Phillips screwdriver. (“B”)

Figure 47.

Removing a 4xGbE Port Filler Panel

A

B

TS000327

Figure 48.

Installing the 4xGbE Port Escutcheon

B

A

TS000328

Advertising