1 removing the led light pipe assembly, Removing the led light pipe assembly – Kontron NSC2U IP Network Server User Manual

Page 109

Advertising
background image

Kontron IP Network Server NSC2U

December 2009

Product Guide, rev. 1.4

109

7. Remove the screw (

Figure 95

, “A”).

8. Remove the embedded USB solid state drive (eUSB SSD), if installed.
9. Remove the two threaded standoffs for the VSSD.

10. Gently work the SFP board backward (“B”), toward the rear of the chassis to

disengage the LED light pipe assembly from behind the front control panel.

11. Pull the SFP board up over the placement peg ("C") and lift it from the chassis.

(“D”)

12. Remove any other components you have installed on the SFP board, such as a

hardware RAID key and DIMM, and put them aside for re-installation on the new

replacement SFP board.

5.3.1

Removing the LED Light Pipe Assembly

1. Note the position of the light pipe assembly so that you will be able to correctly

position it (or a replacement) on the new SFP board during the re-installation

process.

The light pipes extend outward from the SFP board to the front panel control panel.

2. Remove the light pipe assembly by gently pressing the four plastic clips from the

under-side of the SFP board until the bottom of the clips are flush with the bottom

of the SFP board.

3. Gently ease the light pipe assembly from the SFP board.
4. Insert the four plastic clips on the light pipe assembly into the matching holes in

the new SFP board. Insert the clips gently and evenly; do not insert one clip fully

without first partially pressing the others into place.

5.3.2

Installing the Front Panel Board Back into the Chassis

1. Lower the replacement front panel board into the chassis. (

Figure 96

, “A”)

Figure 95.

Removing the Front Panel Board from the Chassis

TS000566