1 cpu 1 and memory cooling area, 2 cpu 2 and chipset cooling area, 3 pci cooling area – Kontron NSC2U IP Network Server User Manual

Page 22: Figure 8

Advertising
background image

NSC2U Server—Features

Kontron IP Network Server NSC2U

Product Guide, rev. 1.4

December 2009

22

2.10.1

CPU 1 and Memory Cooling Area

One of the system’s big fans provides cooling for domain 1, outlined in blue in

Figure 8

.

This fan facilitates the flow of air through the front bezel over the SFP, through the fan,

and over the server board, CPU 1, memory, and ultimately out through the rear of the

chassis.

2.10.2

CPU 2 and Chipset Cooling Area

One of the system’s big fans provides cooling for domain 2, outlined in green in

Figure 8

. This fan facilitates the flow of air through the front bezel over the SFP,

through the fan, and over the server board, CPU 2, chipset and any low-profile PCIe

add-in cards, and ultimately out through the rear of the chassis.

2.10.3

PCI Cooling Area

The two 40Ч40Ч56 mm dual-rotor fans (A in

Figure 8

) facilitate the flow of air through

the front bezel, through the fans, over the server board and any full-length PCI-X or

PCIe add-in cards, and ultimately out through the rear of the chassis.

Figure 8.

NSC2U Server System Cooling Areas

A

B

TS000542

Advertising