1 full-height pci-x/pcie riser card, 2 low-profile pcie riser card, 9 power supply – Kontron NSC2U IP Network Server User Manual

Page 21: 10 system cooling, Full-height pci-x/pcie riser card, Low-profile pcie riser card, Power supply

Advertising
background image

Kontron IP Network Server NSC2U

December 2009

Product Guide, rev. 1.421

Features—NSC2U Server

• The second riser card slot, a low-profile riser card, supports low-profile PCIe add-in

boards.

See

Section 4.2, “Installing or Replacing a PCI Add-in Card” on page 51

, for

instructions describing how to install a PCI-X or PCIe add-in card. After the add-in cards

are installed, the riser assembly is plugged back into the system and the I/O brackets

of all the add-in cards are accessible through the rear panel of the server chassis.

2.8.1

Full-height PCI-X/PCIe Riser Card

The PCI-X/PCIe riser card plugs into the super slot on the the server board. For PCI-X

add-in cards, the super slot riser card implements a 64-bit PCI-X slot with bus speeds

of 66 MHz, 100 MHz, or 133 MHz. For PCIe cards, the super slot has eight PCIe lanes

which can be used for a single x8 add-in card or for one or two x4 or x1 add-in cards.

See

Table 2

for the supported configurations. For detailed information about the

pinouts and electrical specifications, see the Kontron IP Network Server NSC2U

Technical Product Specification.

2.8.2

Low-profile PCIe Riser Card

The low-profile PCIe riser card plugs into the server board and supports the connection

of low-profile PCIe add-in cards only. The low-profile PCIe riser card implements two

×4 link interfaces. Up to two low-profile PCIe add-in cards can be installed. See

Table 3

for the supported configurations. For detailed information about the pinouts and

electrical specifications, see the Kontron IP Network Server NSC2U Technical Product

Specification.

2.9

Power Supply

The power subsystem has up to two power supply modules capable of operating in

redundant mode and a Power Distribution Board (PDB). A power supply filler panel for

the empty power supply site is supplied for systems without redundancy.

The power supply is rated for 600W output capability in full AC (or DC) input voltage

range.

2.10

System Cooling

There are three cooling areas (domains) in the NSC2U Server system:

• domain 1 - CPU 1 and memory; see area outlined in blue in

Figure 8

• domain 2 - CPU 2, chipset, and any low-profile PCIe add-in cards; see area outlined

in green in

Figure 8

• domain 3 - any full length PCI-X or PCIe addin cards; see area outlined in red in

Figure 8

Advertising