Kontron IP Network Server NSC2U

Product Guide, rev. 1.4

December 2009

94

3. Lift the battery assembly out of the case and insert the battery cable through the

opening in the bottom of the case. (

Figure 80

, “B” )

4. Attach the battery cable to the connector on the back of the battery assembly.

(“A”)

5. Put the battery assembly back into the case and close and latch the case lid. (“C”)

6. Place the IBBU on the bracket on the side wall of the chassis. (

Figure 81

, “A”)

7. Slide the IBBU away from the front panel to lock it into place. The plastic tab on

the IBBU case goes into the slot in the chassis (See the red arrow in

Figure 81

).

(“B”)

8. Connect the cable from the IBBU to the connector on the SFP board. (“C”)
9. Re-install the front panel bezel. For instructions, see

Section 3.2.4, “Installing the

Front Bezel” on page 27

10. If this is the last task you are performing, replace the processor air duct and the

top cover of the chassis. Reconnect all the external devices and plug in the power

cord(s).

For information about mounting the server in a rack, see

Section 3.5, “Installing

the Server into a Rack” on page 48

Figure 79.

Connecting the IBBU Power Cable

TS000301

A

B

Figure 80.

Connecting the IBBU Cable through the Battery Case

TS000302

C

B

A