3.3.2.2

Installing the Power Supply Module

1. Press and hold the green safety lock downward and slide the power supply module

into the chassis slot.

3.3.2.3

Grounding a DC-Powered System

The DC chassis provides two #10-32 threaded studs for chassis enclosure grounding. A

single 90º standard barrel, two-hole, compression terminal lug with 5/8-inch pitch

suitable for a #14-10 AWG conductor (such as the Thomas & Betts* terminal lug, p/n

256-31426-141) must be used for proper safety grounding. See “C” in

Figure 3

for the

location of the ground studs.

A crimping tool may be needed to secure the terminal lug to the grounding cable.

3.4

Internal System Component Configuration and Installation

Procedures

Note:

The procedures in this section assume that you have powered down the server and

removed the chassis cover as described in

Section 3.2

,

“General Installation

Procedures”

.

3.4.1

Configuring Jumpers on the Server Board

The jumpers are located on the T5000PAL server board, which is in the rear right

section of the IP Network Server NSC2U chassis. To configure the jumpers on the

server board, you must first remove the chassis cover and then the processor air duct

Figure 16.