Optional Component Installations—NSC2U Server

4.8.1

Installing the RAID Key and RAID DIMM

1. Install the RAID activation key by inserting it into the socket. (

Figure 78

, “C”)

The wider rim is the top side of the key and faces up in the socket.

Make sure the metal clips on the socket snap securely over the edge of the RAID

key top rim.

Caution:

Observe proper ESD and safety procedures when handling the RAID DIMM and the SFP

board.

2. Open the latches on both ends of the RAID DIMM connector header. (

Figure 78

,

“A”)

3. Note the location of the alignment notch (“B”) and insert the DIMM.

Make sure the edge connector on the DIMM aligns properly with the connection

header.

4. Using both hands, press down firmly and evenly on both sides of the DIMM until it

snaps into place and both latches on the connector header close.

4.8.2

Installing the RAID Intelligent Battery Backup Unit (IBBU)

The RAID IBBU is installed on the side wall of the chassis by the SAS Front Panel

(SFP)board. The connector, C8B3, is on the far right-most end of the SFP board. Before

you install it, be sure to remove the front panel bezel.

The IBBU has an internal battery power cable that must be connected.

1. Open the IBBU case lid. If necessary, use a small flat-blade screwdriver to pry open

the lid at the corners. (

Figure 79

, “A”)

2. If the battery power cable is not connected, connect it now. (“B”)

Figure 78.

Installing the RAID DIMM and RAID Key

TS000284

A

A

B

C