3 routing the lan card cables to the front panel, Routing the lan card cables to the front panel – Kontron NSC2U IP Network Server User Manual

Page 61

Advertising
background image

Kontron IP Network Server NSC2U

December 2009

Product Guide, rev. 1.4

61

Optional Component Installations—NSC2U Server

4.5.3

Routing the LAN Card Cables to the Front Panel

In order to access the front panel, the following components must be removed or

disconnected:

• the flex cable
• the PCI fan assembly
• the cable management bracket

1. Disconnect the flex cable from the SAS backplane board at the rear of the drive bay

assembly and move it out of the way of the PCI fan assembly. For instructions, see

Section 5.2.3, “Removing the PCI Fan Assembly” on page 102

.

2. Disconnect the PCI fan assembly power cables and remove the fan assembly from

the chassis. For instructions, see

Section 5.2.3, “Removing the PCI Fan Assembly”

on page 102

3. Remove the cable management bracket by loosening the blue thumbscrew and

pulling the bracket out from under the drive bay assembly. (

Figure 44

, “A” and “B”)

4. Lift the bracket out of the chassis. (“C”)

Once the LAN cables are routed to the front panel and installed there is not enough

room to reconnect the PCI fan assembly power cables. Extensions are provided to

enable the connections.

5. Attach the PCI fan assembly power cable extensions to the connectors on the front

panel board. (

Figure 45

, “A”)

Figure 44.

Removing the Cable Management Bracket

A

B

C

TS000550