1 removing the server board, Removing the server board – Kontron NSC2U IP Network Server User Manual

Page 117

Advertising
background image

Kontron IP Network Server NSC2U

December 2009

Product Guide, rev. 1.4

117

• All DIMMs

Caution:

Before replacing any of the NSC2U Server boards, you must first take the server out of

service, turn off all peripheral devices connected to the system, turn off the system by

pressing the power button, and unplug the power cord(s) from the system or wall

outlet.

When handling this board or any of the components on it, observe the normal safety

and ESD precautions. (See

Appendix A, “Safety Information”

for more information.)

5.6.1

Removing the Server Board

To replace the server board, use the following instructions.

1. Power down the server system and unplug all peripheral devices and the power

cable.

2. Remove the chassis cover and processor air duct. For instructions, see

Section 3.2.1

and

Section 3.2.5

.

3. Remove the PCI riser assembly. For instructions, see

Section 4.2.2, “Removing the

PCI Riser Card Assembly” on page 53

.

4. Remove the CPU fan assembly. For instructions, see

Section 5.2.1, “Removing the

CPU Fans” on page 100

.

5. Remove the drive bay assembly. For instructions, see

Figure 97, “Removing the

Drive Bay Assembly” on page 111

.

6. Disconnect all cables and the bridge board from the server board. Use

Figure 33

,

as a reference.

If you want to re-use components from this server board on the replacement board you

can remove them now or after you have removed the server board from the chassis.

• To remove an I/O expansion module or remote management modules, see

Section

4.3, “Installing an I/O Expansion Module” on page 55

or

Section 4.4, “Installing

Intel® Remote Management Modules” on page 57

.

• To remove DIMMs, see

Section 3.4.4, “Removing Memory DIMMs” on page 42

.

• To remove the heat sink(s) and processor(s), see

Section 3.4.5.2, “Removing a

Processor” on page 44

.

7. Remove the six screws that attach the server board to the chassis. (

Figure 103

,

“A”)

8. Tilt the server board at the front edge and lift it from the chassis. (“B”)

Use caution in pulling it out from beneath the Serial B connector at the rear of the

chassis.