5.5

Replacing the Power Distribution Board

The power distribution board (PDB) routes power from the power supply to the rest of

the server system through an integral wiring harness. The PDB is covered by a metal

cage for safety, ventilation, and heat dissipation reasons. It is this whole assembly that

must be removed and replaced, not just the board.

Caution:

Before replacing any of the boards in the NSC2U Server, you must first take the server

out of service, turn off all peripheral devices connected to the system, turn off the

system by pressing the power button, and unplug the power cord(s) from the system

or wall outlet.

When handling this board, observe the normal safety and ESD precautions. (See

Appendix A, “Safety Information”

for more information.)

To safely remove the PDB, you must first remove the chassis top cover, the front panel

bezel, and the drive bay assembly, which sits in front of the PDB module in the chassis.

5.5.1

Removing the Power Distribution Board

1. Power down the server system and unplug all peripheral devices and the power

cable.

Figure 100. Installing the Drive Bay Assembly

A

B

C

TS000314