7 hard disk drives, 8 riser card assembly, Hard disk drives – Kontron NSC2U IP Network Server User Manual

Page 20: Riser card assembly

Advertising
background image

NSC2U Server—Features

Kontron IP Network Server NSC2U

Product Guide, rev. 1.4

December 2009

20

2.7

Hard Disk Drives

The NSC2U Server chassis supports up to six hot-swappable hard drive tray assemblies

at the front of the chassis.

For information on how to install these drives, see

Section 3.3.1,

“Installing or

Replacing a Hard Drive”

.

Note:

The NSC2U Server does not support all SAS hard drives. For a list of validated hard

drive manufacturers and hard drive types, see the Tested Hardware and Operating

Systems List (THOL) at

http://us.kontron.com/support/

(Search for NSC2U, click on Product Downloads, then

Compatibility Matrix.)

Drives can consume up to 17W of power each. Drives must be specified to run at a

maximum ambient temperature of 45°C.

2.8

Riser Card Assembly

The IP Network Server NSC2U incorporates a PCI riser assembly that supports

installation of PCI-X and PCI Express add-in boards. The assembly includes two riser

cards that provide a total of five standard interface slots for add-in boards by

connecting to two special slots on the T5000PAL server board.

• One of the riser card slots is a PCI super slot that contains all the signals necessary

to support both PCI-X and PCI Express (PCIe) expansion slots. The riser card that

connects to the super slot supports the connection of full-height, full-length PCI-X

or PCIe add-in cards.

Description

Description

A

BIOS Bank Select Jumper

P

CPU Power Connector

B

IO Module Option Connector

Q

Main Power Connector

C

POST Code Diagnostic LEDs

R

Battery

D

Intel

®

Adaptive Slot – Full-height

S

Power Supply Management Connector

E

PCI Express Riser Slot – Low-profile

T

Dual Port USB 2.0 Header

F

System Identification LED - Blue

U

Serial Port Connector

G

External I/O Connectors

V

SSI 24-pin Control Panel Header

H

Status LED – Green/Amber

W

Intel

®

Remote Management Module (RMM)

Connector

I

Serial ‘B’ Port Configuration Jumper

X

System Recovery Jumper Block

J

FBDIMM Slots

Y

Chassis Intrusion Switch Header

K

CPU #1 Connector

Z

3-pin IPMB Header

L

CPU #2 Connector

AA

Intel

®

Local Control Panel Header

M

Voltage Regulator Heat Sink

BB

Serial ‘A’ Header

N

Bridge Board Connector

CC

Intel

®

RMM NIC Connector

O

ATA-100 Optical Drive Connector

(power and I/O)

Note:

In

Figure 7

, connectors shown but not called out are “not used”.

Advertising