9 installing an optical device, Installing an optical device 4.9.1, Figure 81 – Kontron NSC2U IP Network Server User Manual

Page 95: D arrow in

Advertising
background image

Kontron IP Network Server NSC2U

December 2009

Product Guide, rev. 1.4

95

Optional Component Installations—NSC2U Server

4.9

Installing an Optical Device

The optical device is not hot-swappable. To replace a previously installed device or

install a new one, you must first power down the system and remove the chassis cover

and front bezel as described in

Section 3.2, “General Installation Procedures” on

page 25

.

4.9.1

Removing the Optical Device Filler Panel from the Chassis

1. Remove the chassis top cover.
2. Remove the front panel bezel from the chassis to access the optical device slot.
3. Detach the retention clip from the filler panel engagement guide behind the SAS

backplane board. Save it for use on the optical drive.

4. Press on the latch on the back of the engagement guide to release the optical

device filler panel from the backplane. (“A”)

5. Remove the filler panel from the chassis. (“B”)

Figure 81.