Server Component Installations and Upgrades—NSC2U Server

5. Close the load plate completely. (

Figure 32

, “A”)

6. Close the socket lever and ensure that the load plate tab engages under the socket

lever when fully closed. (“B” and “C”)

3.4.5.4

Inserting the Heat Sink

1. If this is a new heat sink (not the one you removed above), remove the protective

film, if present, on the Thermal Interface Material (TIM) located on the bottom of

the heat sink.

2. Set the heat sink over the processor, lining up the four captive screws with the four

posts surrounding the processor. Align the heat sink fins to the front and back of

the chassis for correct airflow (front to back). Use caution and make sure that

cables are not pinched beneath the heat sink. (See

Figure 26

.)

3. Loosely screw in the captive screws on the heat sink corners by tightening one,

then the one diagonally opposite, and so on.

4. Gradually and equally tighten each captive screw in diagonal order until each is

firmly tightened. See

Figure 26

for the order.

Caution:

The torque spec for these screws is 8 inch-pounds. Be careful not to exceed it.