Blocks required – Pilz PSS SB HYD, Basic license User Manual

Page 115

Advertising
background image

Modular Block System: Hydraulic Presses

6-53

- Bit 14:

Strt input constantly high or set too early
Remedy: If

Strt input was not set too early and is constantly

high: Check switch, cable and input card, then reset (input
parameter

Strt).

If

Strt input was set too early: reset again

(input parameter

Strt)

- Bit 15:

Gate closed,

Strt signal is missing

Remedy: Check all conditions and then reset
(input parameter

Strt)

• Error messages on the CPU-display

- None

Global parameters used in administration data block DB015

Global parameters may be set in OB120 using SB070.
• DW1022: Minimum scan time

Blocks required

• DB015:

Administration data block

DB015 must consist of its total length of 1024 data words.
DB015 must have READ/WRITE access.

• SB070

Initialisation of global parameters in DB015