Modular Block System: Hydraulic Presses

6-11

Input coding of selector switch (mode 2 from 6):

RSet:

Reset input for error acknowledgement
RSet = 0/1 signal edge: Reset occurs

LOCK:

Lock switch position
LOCK = 0: Switch position unlocked
LOCK = 1: Switch position locked

If the switch position changes, an error will be
triggered immediately. The parameter

LOCK can

be allocated the flag “Machine running” or “Press
safety valve: on” (input parameter

EIN from

SB 080), for example.

TIME:

Maximum permitted contact switchover time between two
correct switch settings.
Permitted time range: 1 ... 1023 ms

INFORMATION

If possible you should use the PSS(1) DI2 as input module.
If this is not possible, the inputs must use test pulses.