Sb067: feedback loop monitoring, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual

Page 116: Output parameters, Standard function blocks sb067

Advertising
background image

6-54

Modular Block System: Hydraulic Presses

Standard Function Blocks

SB067

SB067: Feedback loop monitoring

Block header

Input parameters

SSNR:

Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).

RFK1:

Feedback loop N/C contact on contactor 1

RFK2:

Feedback loop N/C contact on contactor 2

RSET:

Reset input
RSET = 0/1 signal edge: Trigger reset

Ein:

Switches on main contactor via output parameter

K

Ein = 0/1-signal edge: Switch on output parameter K (K = 1)
Ein = 1/0-signal edge: Switch off output parameter K (K = 0)

Input circuitry
If you are only using one feedback loop, connect the RFK input to

RFK1

and

RFK2.

Output parameters

FG:

Enable bit
FG = 0: Not enabled
FG = 1: No error found on this relay block function

K:

Output to main contactor

SB 067

RFK_K4

B - SSNR
X - RFK1
X - RFK2
X - RSET
X - Ein

FG - X
K

- X