Sb059: two-hand monitoring, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual
Page 78: Standard function blocks, Sb059
6-16
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB059: Two-hand monitoring
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
•
STFG:
Static enable
STFG = 0: Function disabled
STFG = 1: Function enabled
The two-hand control can only be enabled (
FG = 1) if STFG is
high. The
STFG signal is the result when all the signals that
must be present to operate the press are linked (e.g.
FG from
the E-STOP,
FG from the operating mode selector switch etc.)
•
MEin:
Machine “On”
A 1/0-pulse edge on the
MEin signal activates a lock (single-
stroke protection), which will only be lifted when the start
position is achieved (both buttons T1 and T2 released).
MEin = e.g. “Safety valve on” flag: Activation of lock required
MEin = RLO-0 (M 110.00): Activation of lock not required.
SB 059
2_HAND
B - SSNR
X - STFG
X - MEin
X - T1.2
X - T1.4
X - T2.2
X - T2.4
W- KU_S
X - RSET
X - Tipp
X - Auf
X - Off
FG
- X
GST - X
AUF - X
OFF - X
SB059