Modular Block System: Hydraulic Presses

Standard Function Blocks

SB088: Driving/monitoring the position of a dual hydraulic valve
(poppet and directional control valve)

Block header

Input parameters

SSNR:

Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
Value of DW (

SSNR) = 0: No error found

ON:

Start signal for “drive valves” (Y1 and Y2)
ON = 0:

Valves switched off

ON = 0/1 pulse edge: Switch valves on
ON = 1:

Valves switched on

ON = 1/0 pulse edge: Switch valves off
The valves cannot be switched on if the block has detected a
fault (reset lock).
The valves can only be switched on if they are in their start
(off) position (see input parameters

S1 and S2).

S1:

Acknowledgement of valve position (valve 1)
S1 = 1:

Valve in its start position (valve de-energised,
acknowledgement from valve is present)

S2:

Acknowledgement of valve position (valve 2)
S2 = 1:

Valve in its start position (valve de-energised,
acknowledgement from valve is present)

SB088

H_VALV_D

B - SSNR
X - ON
X - S1
X - S2
W - TOn
W - TOff
X - Y1On
X - Y2On
X - VTyp
X - RSET

ENBL - X
Y1

- X

Y2

- X

ERR - X

SB088