Pilz PSS SB HYD, Basic license User Manual

Page 273

Advertising
background image

8-37

Modular Block System: Hydraulic Presses

24 V

Reset

E0.03

(E33.03)

(T/p 1)

A1.00

E0.00

(E33.00)

PSS

(T/p 2)

A1.01

E0.01

(E33.01)

pulsed outputs

3

1

4

2

Safety sensor

not operated

Fig. 8-22: Circuit diagram (descriptions in brackets only for the SafetyBUS p example)

Fig. 8-23: Timing diagram
(E 33.03, M 99.01 and M 116.31 only for the SafetyBUS p example)

PSS Start

E0.00

E0.01

E0.03

M80.00

1

1

1

1

1