Modular Block System: Hydraulic Presses
6-33
•
MRun:
Machine is running
MEin = 0:
Machine standing
MEin = 1:
Machine is running
MEin = 1/0-pulse edge: Activate reset lock.
This parameter can force the operator to carry out a function
test of the gate (gate open/closed).
The reset lock is lifted by carrying out a function test on the
gate followed by the
RSET signal.
•
AuSt:
Automatic start/start-up disabler
AuSt = 0:
Start-up disabler (initial reset is required)
AuSt = 1:
Automatic start/no start-up disabler on PSS cold/
warm start or when starting the I/O-Group; only
effective in conjunction with
NoFT = 1 (see also
under “Operating modes”)
•
ARSt:
Automatic restart/reset lock
ARSt = 0:
Reset lock (reset is required)
ARSt = 1:
Automatic restart/no reset lock
(see also under “Operating modes”)
•
NoFT:
Function test on the gate
NoFT = 0:
Function test required on the gate
NoFT = 1:
Cold/warm start without function test on the gate
(see also under “Operating modes”)
•
RSET:
Reset input
RSET = 0/1 pulse edge:
- Reset errors or
- Reset start-up disabler or
- Reset reset lock