Pilz PSS SB HYD, Basic license User Manual

Page 95

Advertising
background image

Modular Block System: Hydraulic Presses

6-33

MRun:

Machine is running
MEin = 0:

Machine standing

MEin = 1:

Machine is running

MEin = 1/0-pulse edge: Activate reset lock.
This parameter can force the operator to carry out a function
test of the gate (gate open/closed).
The reset lock is lifted by carrying out a function test on the
gate followed by the

RSET signal.

AuSt:

Automatic start/start-up disabler

AuSt = 0:

Start-up disabler (initial reset is required)

AuSt = 1:

Automatic start/no start-up disabler on PSS cold/
warm start or when starting the I/O-Group; only
effective in conjunction with

NoFT = 1 (see also

under “Operating modes”)

ARSt:

Automatic restart/reset lock
ARSt = 0:

Reset lock (reset is required)

ARSt = 1:

Automatic restart/no reset lock

(see also under “Operating modes”)

NoFT:

Function test on the gate
NoFT = 0:

Function test required on the gate

NoFT = 1:

Cold/warm start without function test on the gate

(see also under “Operating modes”)

RSET:

Reset input
RSET = 0/1 pulse edge:

- Reset errors or
- Reset start-up disabler or
- Reset reset lock