6-120

Modular Block System: Hydraulic Presses

Standard Function Blocks

SB086: Overrun control on linear-driven presses

Block header

Input parameters

SSNR:

Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
(See sections entitled “Administration data blocks DB015,
DB016 and DB017” and “Input parameter SSNR” in the
operating manual for the MBS block package).

RQST:

Signal to request an overrun measurement.
RQST = 0/1 pulse edge, request an overrun measurement.
The request will only be accepted if overrun measurement is
not currently running. Removing a request (

RQST = 0) made

during an overrun measurement will not affect how this
measurement is performed.

STRT:

Start signal to set the enable (“ENBL”). If no error is present,
the start signal is simply passed to the “ENBL” output until the
test cam (

TLS) is reached.

STRT = 0: No start signal is present; (stop overrun
measurement)

STRT = 0/1-pulse edge: Start overrun measurement

STRT = 1: Perform overrun measurement

SB086

OVERRUN

B - SSNR
X - RQST
X - STRT
X - ETP
X - TLS
W- MTi
X - RSET

ENBL -

X

OK

-

X