Sb059: two-hand monitoring, Sb061: emergency stop monitoring, Intended use – Pilz PSS SB HYD, Basic license User Manual

Page 34

Advertising
background image

4-4

Intended Use

Modular Block System: Hydraulic Presses

SB059: Two-hand monitoring

The function of standard function block SB059 is determined in
accordance with EN 574, 02/97. It fulfils all the requirements of category 4,
in accordance with EN 954-1, 03/97.

Operating modes:

• Monitoring two buttons (N/C and N/O) in accordance with

EN 954-1, 03/97

• Monitoring the synchronisation time of two buttons (<0.5 s)

• Can also be used to monitor foot switches

INFORMATION
Input circuitry:
• Two-hand buttons must use test pulses.

SB061: Emergency stop monitoring

SB061 is a standard function block for monitoring E-STOP buttons up to
category 4, in accordance with EN 954-1, 03/97 and AK 6, in accordance
with DIN V 19 250, 05/94. It is also possible to use SB061 to monitor
safety gates up to category 4, in accordance with EN 954-1, 03/97.

Operating modes:

• With or without start-up reset on cold-start

• With or without automatic reset when E-STOP is released

INFORMATION
Input circuitry:
• Use E-STOP button with test pulses

• When using SB061 for category 4 applications:

- use dual-channel elements

• When using SB061 for category 2 applications:

- use single-channel elements