Blocks required – Pilz PSS SB HYD, Basic license User Manual
Page 139
Modular Block System: Hydraulic Presses
6-77
- Bit 08:
Protected field broken
Remedy: Clear protected field, reset if necessary
Otherwise: Check ESPE/AOPD outputs, cable, input card and
all conditions and then reset (input parameter
RSET)
- Bit 09:
Start-up disabler
Remedy: Carry out a function test on the ESPE/AOPD (break
protected field and then clear) and then reset (input parameter
RSET)
- Bit 10:
I/O-Group stop triggered while PSS is in normal RUN mode
Remedy: Start I/O-Group
• Error messages on the CPU-display
- E003:
Administration data block has not been initialised
Remedy: Call SB071 in OB120
Global parameters used in the administration data blocks
Global parameters may be set in OB120 using SB071.
• DW1001:
Number of cycles in the contact synchronisation time
between two N/O or N/C contacts
• DW1022:
Minimum scan time
Blocks required
• DB015, DB016, DB017:
Administration data blocks
DB015 must consist of its total length of 1024 data words.
DB015 must have READ/WRITE access.
• SB071
Initialisation of global parameters in DB015, DB016 and DB017