Standard function blocks, Sb088 – Pilz PSS SB HYD, Basic license User Manual

Page 204

Advertising
background image

6-142

Modular Block System: Hydraulic Presses

Standard Function Blocks

WARNING!

If the time values entered for

TOn and TOff are too long, serious injuries

could result should the danger zone be accessed during operation.

The reaction time of the safety valve determines the stopping time of the
press on an emergency stop. The stopping time determines the safety
distance to the tool.

Reaction times should be included in the calculation of the safety
distance if the time values set for the parameters

TOn and TOff are

significantly higher than the actual valve reaction times.

• Please note:

- With directional control valves (input parameter

VTyp = 0), the reaction

time when the valve switches on and off must always be monitored
(see under “Settings for the parameters

TOn and TOff”).

- With poppet valves, the reaction time when the valve switches on and

off may be monitored (see under “Settings for the parameters

TOn and

TOff”).

SB088

Advertising