6-78

Modular Block System: Hydraulic Presses

Standard Function Blocks

Timing diagram

Legend for diagram:

• Signal level:

The ESPE/AOPD is set to have a guarding function, with start-up and
reset lock.

Input parameters:
SSeq = 0:

Start-up disabler (function test required)

ARSt = 0:

Reset lock

GdOn = 1: Operating mode: ESPE/AOPD has guarding function (guard

only)

Abbreviations:
F-Test

Function test

KoSy

Contact synchronisation time between two N/O contacts
This is a global parameter (see also under “Global parameters”
and SB071).

MTD

Maximum permitted duration of test
(150 ms for type 2 ESPE/AOPDs, in accordance with
EN 61 496-1)

SB069

1-Signal
0-Signal