Examples – Pilz PSS SB HYD, Basic license User Manual
Page 286
Advertising
8-50
Examples
Modular Block System: Hydraulic Presses
PSS Start
E 0.00
E 0.04
E 0.01
E 0.02
E 0.08/E 0.09
E 0.05
M 70.00
A 2.16
A 1.00
A 1.01
1
2
3
4
5
6
7
8
Key:
1) Hazardous machine movement
2) Request to open
3) Hazardous machine movements stopped.
Unlocked
4) Gate open
5) Gate closed
6) Request to lock
7) Reset
8) As 1.