Modular Block System: Hydraulic Presses

6-97

ESPE/

AOPD

ESPE/

AOPD

MP2

MP1

Transport
Vehicle

Danger Area

Parallel muting mode
(muting when entering and leaving the danger area)

Fig. 6-3: Muting when entering and leaving the danger area

(parallel muting mode)

Muting signal arrangement

Position MP1/MP2:

Muting signals may come from reflective or send and receive
light barriers, for example. The beams must intersect within
the danger area.

INFORMATION
The overall dimensions stated below must be maintained.

MS1/MS2: Muting signals MS1 and MS2 are not used. The inputs of input

parameters

MS1 and MS2 should be assigned RLO-0

(M 110.00).

INFORMATION
Important additional information on the use of sensors and contacts can
be found under “Safety guidelines” at the end of this SB description.