6-138

Modular Block System: Hydraulic Presses

Standard Function Blocks

VTyp:

Type of valve to be monitored
VTyp = 0:

Monitoring a directional control valve

VTyp = 1:

Monitoring a poppet valve

(see also under “Function”)

RSET:

Error reset
RSET = 0/1 pulse edge: Reset fault

It will only be possible to reset an existing fault if
the valve is in its start (off) position (valve de-
energised and acknowledgement from valve is
present) and no start signal is present (

ON •1).

Output parameters

ENBL:

Enable flag bit
ENBL = 0: Enable locked

When the valves are switched off (input parameter
ON = 1/0 pulse edge), the enable is locked until
the valves return to their start position (input
parameter

S1 = 1 and S2 = 1). This is not an error.

The block will cancel the enable immediately if it
detects a fault.

ENBL = 1: Enable

The block will set the enable if no fault has been
found and the valves are either in operation or in
their start position.

Y1:

Output parameters for operating valve Y1
Y1 = 0:

Valve Y1 off

Y1 = 1:

Valve Y1 on

Y2:

Output parameter for operating valve Y2
Y2 = 0:

Valve Y2 off

Y2 = 1:

Valve Y2 on

ERR:

This output parameter is set as soon as a fault is discovered.
ERR = 0:

No fault found

ERR = 1:

Fault found

SB088