Block header, Input parameters, Standard function blocks – Pilz PSS SB HYD, Basic license User Manual

Page 168: Sb075

Advertising
background image

6-106

Modular Block System: Hydraulic Presses

Standard Function Blocks

SB075: Controlling and monitoring safety gates with guard locking

Block header

Input parameters

SSNR:

Safety subroutine number
Permitted value range: 1 ... 600
Format: Word constants KF000001 ... KF000600
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).

GRP:

I/O-Group status flag (SafetyBUS p) containing the inputs S1,
S2, LCKD and STPD (M116.00 for I/O-Group 0 to M116.31 for
I/O-Group 31)
If the SB is being used without SafetyBUS p, the input
parameter must be assigned RLO-1

S1:

Gate switch: Signal 1

If the gate is closed, both gate

S2:

Gate switch: Signal 2

switches must supply a 1-signal

SB075

SB075

GRD_LCK

W - SSNR
X - GRP
X - S1
X - S2
X - LCKD
W- SyTi
X - MRun
X - STPD
X - RQST
X - ARSt
X - AuSt
X - NoFT
X - BLNK
X - RSET

ENBL -

X

UNLK -

X

SGrd

-

X

SLck

-

X

Advertising