Block header, Input parameters, Standard function blocks – Pilz PSS SB HYD, Basic license User Manual
Page 168: Sb075
6-106
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB075: Controlling and monitoring safety gates with guard locking
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 600
Format: Word constants KF000001 ... KF000600
(see sections in Chapter 5 entitled “Administration data blocks
DB015, DB016 and DB017” and “Input parameter SSNR”).
•
GRP:
I/O-Group status flag (SafetyBUS p) containing the inputs S1,
S2, LCKD and STPD (M116.00 for I/O-Group 0 to M116.31 for
I/O-Group 31)
If the SB is being used without SafetyBUS p, the input
parameter must be assigned RLO-1
•
S1:
Gate switch: Signal 1
If the gate is closed, both gate
•
S2:
Gate switch: Signal 2
switches must supply a 1-signal
SB075
SB075
GRD_LCK
W - SSNR
X - GRP
X - S1
X - S2
X - LCKD
W- SyTi
X - MRun
X - STPD
X - RQST
X - ARSt
X - AuSt
X - NoFT
X - BLNK
X - RSET
ENBL -
X
UNLK -
X
SGrd
-
X
SLck
-
X