4-7

Modular Block System: Hydraulic Presses

INFORMATION
Input circuitry:

• To achieve category 4, two independent shutdown routes must be

provided within the current path of the potentially dangerous drive

• If wiring is to be laid outside the control cabinet, feedback loops must use

test pulses.

• Feedback loops must use test pulses if the possibility of a short-circuit

cannot be excluded.

• If only one contactor is used to switch a potentially dangerous drive, it

must be possible to switch this off via a group contactor within the
current path (selective shutdown).

• The group contactor must also be monitored through a feedback loop.

SB066: Safety gate monitoring

SB066 is designed for monitoring a safety gate. It can monitor a safety
gate with one or two switches.
SB066 meets all the requirements of category 4, in accordance with
EN 954-1, 03/97.

Operating modes:

• Automatic restart

• Automatic start when PSS starts up

Start-up reset when PSS is cold-started

• No function test on the gate

(function test = opening and closing the gate)

INFORMATION
Input circuitry:
• Inputs should have pulsed outputs