Sb097: monitoring muting lamps, Block header, Input parameters – Pilz PSS SB HYD, Basic license User Manual
Page 226: Standard function blocks sb097
6-164
Modular Block System: Hydraulic Presses
Standard Function Blocks
SB097
SB097: Monitoring muting lamps
Block header
Input parameters
•
SSNR:
Safety subroutine number
Permitted value range: 1 ... 200
Format: Byte constants KB001 ... KB200
•
GRP:
On SafetyBUS p applications:
Assign the status flag of the I/O-Group containing inputs
FbL1
and
FbL2 (M 116.00 for I/O-Group 0 to M 116.31 for
I/O-Group 31).
On non-SafetyBUS p applications::
Assign RLO-1 (M 110.01)
•
ON:
Enable signal for muting lamps “ON”
ON = 1: Switch on muting lamps
ON = 0: Switch off muting lamps
This input should be assigned the output signal MAct from
SB 072 (Muting).
•
FbL1:
Feedback input for monitoring filament 1
(Feedback Loop 1)
•
FbL2:
Feedback input for monitoring filament 2
(Feedback Loop 2)
•
RSET:
Input for acknowledging error messages (Reset)
RSET = 0/1-pulse edge: Delete all error entries when the faults
have been rectified.
SB097
MUT_LAMP
B - SSNR
X - GRP
X - ON
X - FbL1
X - FbL2
X - 1OUT
X - RSET
ENBL - X
WARN - X
LMP1 - X
LMP2 - X