Watson-Marlow MM420 User Manual

Page 151

Advertising
background image

Issue 10/06

3 Functions

MICROMASTER 420 Operating Instructions

6SE6400-5AA00-0BP0

151

WARNING

For compound braking, regenerative braking is superimposed on the DC

braking (braking along a ramp). This means that components of the kinetic
energy of the motor and driven load are converted into thermal energy in the
motor. If this power loss is too high or if the braking operation takes too long,
then this can cause the drive to overheat !

When using compound braking it must be expected that there is a higher level

of noise above the compound braking switch-in threshold.

NOTE

Compound braking is de-activated, if

- flying restart is active, and
- DC braking is active is selected.

The compound switch-in threshold V

DC-Comp

is dependent on P1254

V

DC-Comp

(P1254 = 0)

V

DC-Comp

(P1254

0)

a) Auto-detect circuit enabled (P1254 = 1):

- V

DC-Comp

(P1254 = 1) is automatically calculated when the drive inverter

runs-up - i.e. after the line supply voltage has been connected

- Using the auto-detect function, the V

DC-Comp

threshold automatically

adapts itself to the line supply voltage at the particular installation
location.

b) Auto-detect function disabled (P1254 = 0):

-

0210

2

13

.

1

,

P

V

Comp

DC

=

- The

V

DC-Comp

threshold is immediately re-calculated after entering P0210

- P0210 must be adapted to the particular installation location