Watson-Marlow MM420 User Manual

Page 169

Advertising
background image

Issue 10/06

3 Functions

MICROMASTER 420 Operating Instructions

6SE6400-5AA00-0BP0

169

f

U, M, P,

Φ

Voltage control range

Field control range

Rated motor

operating point

M

n

,

Φ

n

f

n

f

max

M,

Φ

U, P

U, P

Fig. 3-73

Operating ranges and characteristics of an induction motor when fed from a
drive inverter

There are several versions of the V/f characteristic as shown in Table 3-34.

Table 3-34

V/f characteristic (parameter P1300)

Parameter

value

Significance Use / property

0 Linear

character-

istic

Standard case

V

n

0

f

n

V

f

P1300 = 0

1

FCC

Characteristic which compensates the voltage losses of the stator
resistance for static (steady-state) or dynamic loads (flux current control
FCC). This is especially used for small motors which have a relatively high
stator resistance. Refer to Section 3.21.1.2.

2 Square-law

character-

istic

This is a characteristic which
takes into consideration the
torque characteristic of the driven
load (e.g. fan / pump)
a) Square-law characteristic

(f

2

characteristic)

b) Energy saving as the lower

voltage also results in lower
currents and losses.

V

n

0

f

n

V

f

P1300 = 2

3 Programm-

able

character-

istic

Characteristic which takes into
consideration the torque
characteristic of the motor /
driven load (e.g. synchronous
motor).

V

P1325

f1

P1320

f

max

P1082

V

max

r0071

V

n

P0304

P1323

P1321

f0

0 Hz

f2

P1322

f3

P1324

f

n

P0310

f

P1300 = 3

P1310

Advertising