5 classification of emc performance, Class 1: general industrial, Class 2: filtered industrial – Watson-Marlow MM420 User Manual

Page 196

Advertising
background image

Changing the Operator Panel

Issue 10/06

MICROMASTER 420 Operating Instructions

196

6SE6400-5AA00-0BP0

7.1.5

Classification of EMC performance

Three General classes of EMC performance are available as detailed below:

Class 1: General Industrial

Compliance with the EMC Product Standard for Power Drive Systems EN 61800-3
for use in Second Environment (Industrial).

Table 7-2

Class 1 - General Industrial

EMC Phenomenon

Standard

Level

Radiated Emissions

EN 55011

Level A1

Emissions:

Conducted Emissions

EN 61800-3

Limits complying with EN 55011,
Class A, Group 2

Electrostatic Discharge

EN 61000-4-2

8 kV air discharge

Burst Interference

EN 61000-4-4

2 kV power cables, 1 kV control

Immunity:

Radio Frequency
Electromagnetic Field

EN 61000-4-3

26-1000 MHz, 10 V/m

Class 2: Filtered Industrial

This level of performance will allow the manufacturer/assembler to self-certify their
apparatus for compliance with the EMC directive for the industrial environment as
regards the EMC performance characteristics of the power drive system.
Performance limits are as specified in the Generic Industrial Emissions and
Immunity standards EN 61000-6-4 and EN 61000-6-2.

Table 7-3

Class 2 - Filtered Industrial

EMC Phenomenon

Standard

Level

Radiated Emissions

EN 55011

Limit A1

Emissions:

Conducted Emissions

EN 61800-3

Limits complying with EN
55011, Class A, Group 2

Supply Voltage Distortion

EN 61000-2-4

Voltage Fluctuations, Dips,
Unbalance, Frequency
Variations

EN 61000-2-1

Magnetic Fields

EN 61000-4-8

50 Hz, 30 A/m

Electrostatic Discharge

EN 61000-4-2

8 kV air discharge

Burst Interference

EN 61000-4-4

2 kV power cables,
2 kV control

Radio Frequency
Electromagnetic Field,
amplitude modulated

EN 61000-4-3

80-1000 MHz, 10 V/m, 80%
AM, power and signal lines

Immunity:

Radio-frequency
Electromagnetic Field,
pulse modulated

EN 61000-4-3

900 MHz, 10 V/m 50% duty
cycle, 200 Hz repetition rate

Advertising