background image

4 Troubleshooting

Issue 10/06

MICROMASTER 420 Operating Instructions

180

6SE6400-5AA00-0BP0

4.3

Fault messages and alarm messages

4.3.1

Fault messages

In the event of a failure, the inverter switches off and a fault code appears on the
display.

NOTE
To reset the fault code, one of three methods listed below can be used:
1. Cycle the power to the drive.
2. Press the

button on the BOP or AOP.

3. Via Digital Input 3 (default setting)

Fault messages are stored in parameter r0947 under their code number (e.g.
F0003 = 3). The associated error value is found in parameter r0949. The value 0 is
entered if a fault has no error value. It is furthermore possible to read out the point
in time that a fault occurred (r0948) and the number of fault messages (P0952)
stored in Parameter r0947.
A detailed description of the fault messages is provided in the parameter list.

4.3.2 Alarm

messages

Alarm messages are stored in parameter r2110 under their code number (e.g.
A0503 = 503) and can be read out from there.
A detailed description of the alarm messages is provided in the parameter list.