Watson-Marlow MM420 User Manual

Page 40

Advertising
background image

3 Functions

Issue 10/06

MICROMASTER 420 Operating Instructions

40

6SE6400-5AA00-0BP0

Table 3-1

Parameter attributes

Attribute

group

Attribute Description

The data type of a parameter defines the maximum possible value range. 3 data
types are used for MICROMASTER. They either represent an unsigned integer value
(U16, U32) or a floating-point value (float). The value range is frequently restricted by
a minimum, maximum value (min, max) or using drive inverter/motor quantities.

U16

Unsigned, integer value with a size of 16 bits,
max. value range: 0 .... 65535

U32

Unsigned, integer value with a size of 32 bits
max. value range: 0 .... 4294967295

Data types

Float

A simple precise floating point value according to the IEEE standard format
max. value range: -3.39e

+38

– +3.39e

+38

The value range, which is specified as a result of the data type, is restricted/limited by
the minimum, maximum value (min, max) and using drive inverter/motor quantities.
Straightforward commissioning (start-up) is guaranteed in so much that the
parameters have a default value. These values (min, def, max) are permanently
saved in the drive inverter and cannot be changed by the user.

-

No value entered (e.g.: "r parameter")

Min Minimum

value

Def Default

value

Value range

Max Maximum

value

For MICROMASTER, the units of a particular parameter involve the physical quantity
(e.g. m, s, A). Quantities are measurable properties/characteristics of physical
objects, operations, states and are represented using characters of a formula (e.g. V
= 9 V).

- No

dimension

% Percentage

A Ampere
V Volt

Ohm Ohm

us Microseconds

ms Milliseconds

s Seconds

Hz Hertz

kHz Kilohertz

1/min

Revolutions per minute [RPM]

m/s

Meters per second

Nm Newton

meter

W Watt

kW Kilowatt

Hp Horse

power

kWh Kilowatt

hours

°C Degrees

Celsius

m Meter

kg Kilograms

Unit

°

Degrees (angular degrees)