Watson-Marlow MM420 User Manual

Page 189

Advertising
background image

Issue 10/06

5 MICROMASTER 420 specifications

MICROMASTER 420 Operating Instructions

6SE6400-5AA00-0BP0

189

Input voltage range

3 AC 380 V – 480 V, ± 10 %

(with built in Class A Filter)

Order No.

6SE6420- 2AD22-

2BA1

2AD23-

0BA1

2AD24-

0BA1

2AD25-

5CA1

2AD27-

5CA1

2AD31-

1CA1

[kW] 2.2 3.0 4.0 5.5

7.5 11.0

Output Rating

[hp] 3.0 4.0 5.0 7.5 10.0 15.0

Output Power

[kVA]

4.5

5.9

7.8

10.1

14.0

19.8

Input

Current

1)

[A]

7.5 10.0 12.8 15.6 22.0 32.3

Output

Current

[A]

5.9 7.7 10.2 13.2 19.0 26.0

Fuse

[A] 16 16 20 20 25 35

Recommended 3NA 3805 3805 3807 3807 3810 3814
For UL specified

* * * * * *

[mm

2

]

1.0 1.0 1.5 2.5 4.0 6.0

Input Cable, min.

[awg]

18 18 16 14 12 10

[mm

2

] 6.0

6.0

6.0

10.0 10.0 10.0

Input Cable, max.

[awg] 10 10 10 8

8

8

[mm

2

]

1.0 1.0 1.0 1.5 2.5 4.0

Output Cable, min.

[awg]

18 18 18 16 14 12

[mm

2

] 6.0

6.0

6.0

10.0 10.0 10.0

Output Cable, max.

[awg] 10 10 10 8

8

8

[kg] 3.1 3.3 3.3 5.4 5.7 5.7

Weight

[lbs] 6.8 7.3 7.3 11.9 12.5 12.5

1) Secondary conditions: Input current at the rated operating point - applies for the short-circuit voltage of the line

supply V

k

= 2 % referred to the rated drive converter power and a rated line supply voltage

of 400 V without line commutating reactor.

* UL listed fuses such as Class NON from Bussmann are required for use in America

Advertising