Configuring link monitoring, Configuring errored frame event detection, Configuring errored frame period event detection – H3C Technologies H3C S12500 Series Switches User Manual

Page 25: Configuring errored frame seconds event detection

Advertising
background image

14

Configuring link monitoring

CAUTION:

Make sure the errored frame seconds triggering threshold is less than the errored frame seconds detection
interval. Otherwise, no errored frame seconds event can be generated.

Configuring errored frame event detection

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure the errored frame
event detection interval.

oam errored-frame period
period-value

Optional.
1 second by default.

3.

Configure the errored frame

event triggering threshold.

oam errored-frame threshold
threshold-value

Optional.
1 by default.

Configuring errored frame period event detection

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure the errored frame

period event detection period.

oam errored-frame-period period
period-value

Optional.
1000 milliseconds by default.

3.

Configure the errored frame
period event triggering

threshold.

oam errored-frame-period
threshold threshold-value

Optional.
1 by default.

Configuring errored frame seconds event detection

Step Command

Remarks

1.

Enter system view.

system-view

N/A

2.

Configure the errored frame
seconds event detection

interval.

oam errored-frame-seconds
period period-value

Optional.
60 second by default.

3.

Configure the errored frame
seconds event triggering

threshold.

oam errored-frame-seconds
threshold threshold-value

Optional.
1 by default.

NOTE:

After Ethernet OAM connections are established, the link monitoring periods and thresholds configured in
this section take effect on all Ethernet ports automatically.