H3C Technologies H3C S12500 Series Switches User Manual

Page 64

Advertising
background image

53

Interface Gigabitethernet2/0/2

DLDP port state : advertisement

DLDP link state : up

The neighbor number of the port is 1.

Neighbor mac address : 0023-8956-3600

Neighbor port index : 60

Neighbor state : two way

Neighbor aged time : 12

The output shows that both Gigabitethernet 2/0/1 and Gigabitethernet 2/0/2 are in

Advertisement state, which means both links are bidirectional.
# Enable system information monitoring on Device A, and enable the display of log and trap
information.

[DeviceA] quit

<DeviceA> terminal monitor

<DeviceA> terminal logging

<DeviceA> terminal trapping

The following log and trap information is displayed on Device A:

<DeviceA>

#Jan 18 18:10:38:481 2010 DeviceA DLDP/1/TrapOfUnidirectional: -Slot=2; Trap

1.3.6.1.4.1.25506.2.43.2.1.1<hh3cDLDPUnidirectionalPort> : DLDP detects a

unidirectional link in port 17825792.

%Jan 18 18:10:38:481 2010 DeviceA DLDP/3/DLDP_UNIDIRECTION_MANUAL: -Slot=2; DLDP

detects a unidirectional link on port Gigabitethernet2/0/1. The transceiver has

malfunction in the Tx direction or cross-connected links exist between the local device

and its neighbor. The shutdown mode is MANUAL. The port needs to be shut down by the

user.

#Jan 18 18:10:38:618 2010 DeviceA DLDP/1/TrapOfUnidirectional: -Slot=2;

1.3.6.1.4.1.25506.2.43.2.1.1<hh3cDLDPUnidirectionalPort> : DLDP detects a

unidirectional link in port 17825793.

%Jan 18 18:10:38:618 2010 DeviceA DLDP/3/DLDP_UNIDIRECTION_MANUAL: -Slot=2; DLDP

detects a unidirectional link on port Gigabitethernet2/0/2. The transceiver has

malfunction in the Tx direction or cross-connected links exist between the local device

and its neighbor. The shutdown mode is MANUAL. The port needs to be shut down by the

user.

The output shows that DLDP has detected a unidirectional link on both Gigabitethernet 2/0/1 and

Gigabitethernet 2/0/2, and is asking you to shut down the faulty ports manually.
After you shut down Gigabitethernet 2/0/1 and Gigabitethernet 2/0/2, the following log

information is displayed:

<DeviceA> system-view

[DeviceA] interface gigabitethernet 2/0/1

[DeviceA-Gigabitethernet2/0/1] shutdown

%Jan 18 18:16:12:044 2010 DeviceA IFNET/3/LINK_UPDOWN: Gigabitethernet2/0/1 link

status is DOWN.

[DeviceA-Gigabitethernet2/0/1] quit

[DeviceA] interface gigabitethernet 2/0/2

[DeviceA-Gigabitethernet2/0/2] shutdown

%Jan 18 18:18:03:583 2010 DeviceA IFNET/3/LINK_UPDOWN: Gigabitethernet2/0/2 link

status is DOWN.